Cookies on this site

Embryonic development in normal and genetically modified mice is commonly analysed by histological sectioning. This procedure is time-consuming, prone to artefact, and results in the loss of three-dimensional (3D) information. Magnetic resonance imaging (MRI) of embryos has the potential of noninvasively acquiring a complete 3D data set. Published methods have used spin-echo techniques with inherently high signal-to-noise ratio (SNR); however, they required either perfusion of the embryo with a contrast agent, or prolonged acquisition times to improve contrast and resolution. Here, we show that a standard preparation (i.e. paraformaldehyde fixation) of 15.5 days post-coitum embryos followed by MRI using a fast gradient-echo sequence with T(1)-weighting achieves high resolution and high throughput for investigating mouse embryonic anatomy. 3D data sets were acquired in overnight experiments (<9 h) with an experimental resolution of approximately 25 microm(3). This spatial resolution is twofold higher than the values reported previously for comparable paraformaldehyde-fixed embryos, and it was obtained in less than a quarter of the time with sufficient SNR. Our approach combines speed, high resolution and contrast with a simple preparation technique and minimal operator time (<1 h). It allows rapid routine 3D characterisation of normal and abnormal mouse embryonic anatomy.

More information

DOI

10.1007/s10334-003-0002-z

Type

Journal article

Publication Date

01/02/2003

Volume

16

Pages

43 - 51

Total pages

8

Keywords

Anatomy, Cross-Sectional, Animals, Echo-Planar Imaging, Fetus, Image Enhancement, Imaging, Three-Dimensional, Mice, Mice, Inbred C57BL, Sensitivity and Specificity